B Series: construction and selection data

Reorganized from the applicable LMConn source-catalog pages. Final dimensions, contact ratings, keying and wiring remain controlled by the approved drawing.

Product familiesB Series
Documented pin counts2-pin, 3-pin, 4-pin, 5-pin, 6-pin, 7-pin, 8-pin, 9-pin, 10-pin, 12-pin, 14-pin, 16-pin, 18-pin, 19-pin, 20-pin, 22-pin, 24-pin, 26-pin, 30-pin, 32-pin
Product constructions13
Source PDF pages9, 8

Mechanical and environmental data

Ingress protection
IP50
Mating endurance
More than 5,000 mating cycles
Vibration
10-2,000 Hz, 15 g
Mechanical shock
100 g, 6 ms
Salt-spray reference
More than 144 hours
Temperature reference
-55 C to +250 C
Shielding reference
More than 75 dB at 10 MHz; more than 40 dB at 1 GHz

Construction range

floating cable receptacle, fixed plug, front-sealed cable plug, front-sealed cable plug with protective cap, straight cable plug, right-angle cable plug, double-nut receptacle, double-nut PCB receptacle.

  • Select plug, free receptacle, fixed receptacle, panel or PCB format.
  • Confirm straight or right-angle cable exit and available installation space.
  • Match the pin count, insert orientation, contact gender and keying to the mating component.
  • Define solder, crimp, PCB or factory-molded cable termination.
  • Release cable diameter, shielding, jacket, pin map and required tests on the drawing.
How to read the ordering code

From connector format to a controlled configuration

  1. Body stylePlug or receptacle, straight, right-angle, panel or PCB construction.
  2. Key and shellKey orientation and shell-size family establish mechanical compatibility.
  3. InsertContact arrangement, contact gender and pin numbering define the electrical interface.
  4. MaterialsShell finish, insulator and contact material are selected for environment and duty.
  5. TerminationSolder, crimp, PCB, collet, cable nut or overmold completes the released build.
B-DHG Floating Cable Receptacle with Nut or Collet
PP-B-011B-DHG Floating Cable Receptacle with Nut or Collet2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-TAG Fixed Push-Pull Plug
PP-B-006B-TAG Fixed Push-Pull Plug2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-TEG Front-Sealed Push-Pull Plug with Collet
PP-B-004B-TEG Front-Sealed Push-Pull Plug with Collet2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-TEG Front-Sealed Push-Pull Plug with Protective Cap and Lanyard
PP-B-005B-TEG Front-Sealed Push-Pull Plug with Protective Cap and Lanyard2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-TGG Straight Push-Pull Plug with Cable Nut
PP-B-001B-TGG Straight Push-Pull Plug with Cable Nut2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-TGG Straight Push-Pull Plug with Collet Backshell
PP-B-002B-TGG Straight Push-Pull Plug with Collet Backshell2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-THG 90-Degree Push-Pull Plug with Nut or Collet
PP-B-003B-THG 90-Degree Push-Pull Plug with Nut or Collet2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
B-ZCG Double-Nut Receptacle for Solder Wire or PCB
PP-B-009B-ZCG Double-Nut Receptacle for Solder Wire or PCB2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · PCB termination
B-ZCG Double-Nut Receptacle with Long Right-Angle PCB Pins
PP-B-010B-ZCG Double-Nut Receptacle with Long Right-Angle PCB Pins2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Right-angle PCB termination
B-ZEG External Fixed Receptacle for Solder Wire or PCB
PP-B-008B-ZEG External Fixed Receptacle for Solder Wire or PCB2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · PCB termination
B-ZGG Internal Fixed Receptacle for Solder Wire or PCB
PP-B-007B-ZGG Internal Fixed Receptacle for Solder Wire or PCB2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · PCB termination
B-ZPG 90-Degree Short-Pin PCB Receptacle
PP-B-012B-ZPG 90-Degree Short-Pin PCB Receptacle2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Right-angle PCB termination
B-ZXG Double-Nut 90-Degree Short-Pin PCB Receptacle
PP-B-013B-ZXG Double-Nut 90-Degree Short-Pin PCB Receptacle2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 19, 20, 22, 24, 26, 30, 32 contacts / pins · Right-angle PCB termination

What B Series Push-Pull Connectors are designed to solve

Direct answer: B Series is the broad starting point for compact metal push-pull connectivity where quick mating and a wide choice of plug and receptacle formats are required.

The best result comes from matching the connector and cable to the complete system—not selecting by diameter or appearance alone. This page organizes the decisions an engineer, buyer or system integrator needs to make before requesting a drawing or quotation.

LMConn groups compatible formats by locking method, interface size, contact arrangement, installation method and cable construction. This makes it possible to compare standard options while keeping project-specific details such as pin mapping, cable length, labels and validation requirements under controlled revision.

Available product directions

Option 01

Straight plug

Use this configuration when the equipment layout and mating interface call for straight plug. Confirm the exact drawing, electrical limits and mating component before release.

Option 02

Right-angle plug

Use this configuration when the equipment layout and mating interface call for right-angle plug. Confirm the exact drawing, electrical limits and mating component before release.

Option 03

Fixed receptacle

Use this configuration when the equipment layout and mating interface call for fixed receptacle. Confirm the exact drawing, electrical limits and mating component before release.

Option 04

Jam-nut receptacle

Use this configuration when the equipment layout and mating interface call for jam-nut receptacle. Confirm the exact drawing, electrical limits and mating component before release.

Option 05

Elbow PCB receptacle

Use this configuration when the equipment layout and mating interface call for elbow pcb receptacle. Confirm the exact drawing, electrical limits and mating component before release.

Manual-derived technical content

Catalog-derived parameters with original LMConn visuals

The following technical values are taken from the supplied source manuals rather than inferred from general connector practice. The accompanying image is an original LMConn presentation visual and is not a model-specific engineering drawing. Family-level data summarizes the catalog; ordering dimensions and electrical limits must still be checked against the exact model row and contact layout.

Shell sizes shown00B, 0B, 1B, 2B, 3B, 4B
Protection ratingIP50
Mating cycles>5,000
Insulation resistance>5,000 MΩ
Contact resistance<10 mΩ
Working temperature-55°C to +250°C (catalog family data)

Product appearance varies by shell size, contact layout, mounting and cable configuration. Request the current model drawing and approved sample for final verification.

Engineering selection guide

  1. Select shell size 00B through larger formats as required. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  2. Choose multipole or coaxial contact arrangement. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  3. Decide between collet and sealed cable clamping. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  4. Match receptacle mounting thread and panel thickness. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  5. Confirm keying and insert orientation. Record the requirement in the interface-control drawing or RFQ so it can be verified.

Information that controls the design

DecisionQuestions to answerWhy it matters
ElectricalSignal, protocol, voltage, current, contact count and shielding?Controls insert layout, contact size, cable and test plan.
MechanicalMounting, straight/angle exit, panel thickness, mating access?Controls envelope, cutout and serviceability.
EnvironmentDust, water, chemicals, temperature, vibration and mating cycles?Controls sealing, material and strain-relief choices.
CableStatic, flex, torsion, conductor size, jacket and outside diameter?Controls backshell, gland, bend radius and lifetime.
QualityInspection, electrical test, labels, traceability and packaging?Creates an objective acceptance standard.

Important: Ratings differ by exact part number, contact layout, cable and assembly condition. Values shown on a family page are selection guidance, not a substitute for the approved product drawing and datasheet.

Typical applications and design priorities

Instrumentation

For instrumentation, engineers normally prioritize connection security, routing space and service access. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Medical devices

For medical devices, engineers normally prioritize signal integrity, environmental protection and repeatable installation. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Measurement systems

For measurement systems, engineers normally prioritize connection security, routing space and service access. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Industrial controls

For industrial controls, engineers normally prioritize signal integrity, environmental protection and repeatable installation. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Portable equipment

For portable equipment, engineers normally prioritize connection security, routing space and service access. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

How to compare candidate products

Begin with non-negotiable interface requirements, then compare environmental and assembly details. Do not use a single headline rating as the sole decision. A suitable candidate should match the mating geometry, contact map, electrical load, cable construction, mounting envelope and maintenance method.

For replacement projects, send photographs only as supporting information. Measurements, existing part numbers, panel cutouts and pin assignments are needed because many circular connectors have similar external shapes. For new designs, reserve space for the connector body, coupling action, minimum cable bend radius and an operator’s hand or assembly tool.

RFQ checklist

  • Target quantity, prototype quantity and annual demand.
  • Connector family, mating component or interface drawing.
  • Contact count, gender, coding, keying and pin assignment.
  • Voltage, current, signal type, network protocol and shield strategy.
  • Mounting method, panel thickness and available installation space.
  • Cable type, length, conductor size, flex requirements and jacket material.
  • Ingress protection, temperature, vibration and chemical exposure.
  • Required tests, labeling, documentation and packaging.

Frequently asked questions

What is B Series Push-Pull used for?

B Series is the broad starting point for compact metal push-pull connectivity where quick mating and a wide choice of plug and receptacle formats are required. Common uses include instrumentation, medical devices, measurement systems. Final suitability depends on the selected part number and operating conditions.

How do I select the correct B series push pull connector?

Start with the mating interface, electrical function and environment. Then confirm mounting, contact layout, termination, cable diameter and keying. The selection checklist on this page captures the minimum information needed for an engineering review.

Are all B series push pull connector products interchangeable?

No. Products that look similar may differ in thread, shell size, keying, contact layout, insert orientation, sealing and dimensions. Always compare the complete dimensional drawing and mating-part definition.

Which specifications should I send for a quotation?

Send quantity, drawings or mating part, contact count, pinout, voltage and current, signal or protocol, cable type and length, environmental rating, mounting style and any testing or labeling requirements.

Can LMConn configure a custom version?

Configuration can cover contact layout, cable length, connector orientation, pin mapping, shielding, overmolding, labels and packaging where technically feasible. A drawing review is required before production.

How is the final part verified?

Verification should be defined by the project and may include dimensional inspection, continuity, insulation resistance, contact resistance, high-potential testing, shield continuity and visual checks. Required tests must be agreed in the specification.

Need a connector selected or a cable built around your equipment?

Discuss your project