Home / M12 A-Coded Connectors
LMCONN / PRECISION INTERCONNECT SYSTEMS

M12 A-Coded Connectors

A-coded M12 connectors for sensors, actuators, DC signal and device connections in 3-, 4-, 5-, 6-, 8-, 12- and 17-contact layouts.

Matching LMConn products

Explore products for M12 A-Coded Connectors

21 linked product pages
Open any product to review images, pin options and technical data.

Catalog-derived engineering summary

M12 A-Coded Connectors: construction and selection data

Reorganized from the applicable LMConn source-catalog pages. Final dimensions, contact ratings, keying and wiring remain controlled by the approved drawing.

Product familiesM12
Documented pin counts3-pin, 4-pin, 5-pin, 6-pin, 8-pin, 12-pin, 17-pin
Product constructions21
Source PDF pages10, 11, 12

Mechanical and environmental data

Ingress protection
Depends on selected body, seal and panel interface
Mating endurance
Confirm for the selected contact system
Vibration
Confirm against the approved application specification
Mechanical shock
Confirm against the approved application specification
Salt-spray reference
Material and finish dependent
Temperature reference
Connector, contact and cable material dependent
Shielding reference
Construction and cable dependent

Construction range

metal male field connector, metal female field connector, metal male right-angle connector, metal female right-angle connector, plastic male field connector, plastic female field connector, plastic male right-angle connector, plastic female right-angle connector.

  • Select plug, free receptacle, fixed receptacle, panel or PCB format.
  • Confirm straight or right-angle cable exit and available installation space.
  • Match the pin count, insert orientation, contact gender and keying to the mating component.
  • Define solder, crimp, PCB or factory-molded cable termination.
  • Release cable diameter, shielding, jacket, pin map and required tests on the drawing.
How to read the ordering code

From connector format to a controlled configuration

  1. Body stylePlug or receptacle, straight, right-angle, panel or PCB construction.
  2. Key and shellKey orientation and shell-size family establish mechanical compatibility.
  3. InsertContact arrangement, contact gender and pin numbering define the electrical interface.
  4. MaterialsShell finish, insulator and contact material are selected for environment and duty.
  5. TerminationSolder, crimp, PCB, collet, cable nut or overmold completes the released build.
M12 Metal Field-Wireable Male Straight Connector
TH-M12-001M12 Metal Field-Wireable Male Straight Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Metal Field-Wireable Female Straight Connector
TH-M12-002M12 Metal Field-Wireable Female Straight Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Metal Field-Wireable Male Right-Angle Connector
TH-M12-003M12 Metal Field-Wireable Male Right-Angle Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Metal Field-Wireable Female Right-Angle Connector
TH-M12-004M12 Metal Field-Wireable Female Right-Angle Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Plastic Field-Wireable Male Straight Connector
TH-M12-005M12 Plastic Field-Wireable Male Straight Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Plastic Field-Wireable Female Straight Connector
TH-M12-006M12 Plastic Field-Wireable Female Straight Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Plastic Field-Wireable Male Right-Angle Connector
TH-M12-007M12 Plastic Field-Wireable Male Right-Angle Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Plastic Field-Wireable Female Right-Angle Connector
TH-M12-008M12 Plastic Field-Wireable Female Right-Angle Connector3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Front-Mount Male Panel Receptacle Type 1
TH-M12-009M12 Front-Mount Male Panel Receptacle Type 13, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Front-Mount Male Panel Receptacle Type 2
TH-M12-010M12 Front-Mount Male Panel Receptacle Type 23, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Front-Mount Male Panel Receptacle Type 3
TH-M12-011M12 Front-Mount Male Panel Receptacle Type 33, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Front-Mount Female Panel Receptacle
TH-M12-012M12 Front-Mount Female Panel Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Rear-Mount Female Panel Receptacle
TH-M12-013M12 Rear-Mount Female Panel Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Front-or-Rear-Mount Male Bulkhead Receptacle
TH-M12-014M12 Front-or-Rear-Mount Male Bulkhead Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Square-Flange Male Panel Receptacle
TH-M12-015M12 Square-Flange Male Panel Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Square-Flange Female Panel Receptacle
TH-M12-016M12 Square-Flange Female Panel Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Solder, crimp, PCB or cable termination according to selected construction
M12 Male 90-Degree PCB Panel Receptacle
TH-M12-017M12 Male 90-Degree PCB Panel Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Right-angle PCB termination
M12 Female 90-Degree PCB Panel Receptacle
TH-M12-018M12 Female 90-Degree PCB Panel Receptacle3, 4, 5, 6, 8, 12, 17 contacts / pins · Right-angle PCB termination
M12 Field-Wireable Male Connector with Shield Options
TH-M12-019M12 Field-Wireable Male Connector with Shield Options3, 4, 5, 6, 8, 12, 17 contacts / pins · Field-wireable termination
M12 Molded Male Cable Connector Straight or Right-Angle
TH-M12-020M12 Molded Male Cable Connector Straight or Right-Angle3, 4, 5, 6, 8, 12, 17 contacts / pins · Factory overmolded cable termination
M12 Molded Female Cable Connector Straight or Right-Angle
TH-M12-021M12 Molded Female Cable Connector Straight or Right-Angle3, 4, 5, 6, 8, 12, 17 contacts / pins · Factory overmolded cable termination

What M12 A-Coded Connectors are designed to solve

Direct answer: A coding covers the broadest contact-count range in the supplied M12 catalog and is the primary search path for sensor and general signal connections.

The best result comes from matching the connector and cable to the complete system—not selecting by diameter or appearance alone. This page organizes the decisions an engineer, buyer or system integrator needs to make before requesting a drawing or quotation.

LMConn groups compatible formats by locking method, interface size, contact arrangement, installation method and cable construction. This makes it possible to compare standard options while keeping project-specific details such as pin mapping, cable length, labels and validation requirements under controlled revision.

Available product directions

Option 01

A-coded field-wireable plug

Use this configuration when the equipment layout and mating interface call for a-coded field-wireable plug. Confirm the exact drawing, electrical limits and mating component before release.

Option 02

A-coded molded cable

Use this configuration when the equipment layout and mating interface call for a-coded molded cable. Confirm the exact drawing, electrical limits and mating component before release.

Option 03

A-coded front panel receptacle

Use this configuration when the equipment layout and mating interface call for a-coded front panel receptacle. Confirm the exact drawing, electrical limits and mating component before release.

Option 04

A-coded rear panel receptacle

Use this configuration when the equipment layout and mating interface call for a-coded rear panel receptacle. Confirm the exact drawing, electrical limits and mating component before release.

Option 05

A-coded right-angle connector

Use this configuration when the equipment layout and mating interface call for a-coded right-angle connector. Confirm the exact drawing, electrical limits and mating component before release.

Manual-derived technical content

Catalog-derived parameters with original LMConn visuals

The following technical values are taken from the supplied source manuals rather than inferred from general connector practice. The accompanying image is an original LMConn presentation visual and is not a model-specific engineering drawing. Family-level data summarizes the catalog; ordering dimensions and electrical limits must still be checked against the exact model row and contact layout.

Contact count3, 4, 5, 6, 8, 12 and 17 contacts
Protection ratingIP65-IP67

Product appearance varies by shell size, contact layout, mounting and cable configuration. Request the current model drawing and approved sample for final verification.

Engineering selection guide

  1. Choose contact count from the equipment pinout. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  2. Match male/female contact face. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  3. Select straight or right-angle exit. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  4. Choose field-wireable, molded or panel format. Record the requirement in the interface-control drawing or RFQ so it can be verified.
  5. Verify voltage and current for the exact insert. Record the requirement in the interface-control drawing or RFQ so it can be verified.

Information that controls the design

DecisionQuestions to answerWhy it matters
ElectricalSignal, protocol, voltage, current, contact count and shielding?Controls insert layout, contact size, cable and test plan.
MechanicalMounting, straight/angle exit, panel thickness, mating access?Controls envelope, cutout and serviceability.
EnvironmentDust, water, chemicals, temperature, vibration and mating cycles?Controls sealing, material and strain-relief choices.
CableStatic, flex, torsion, conductor size, jacket and outside diameter?Controls backshell, gland, bend radius and lifetime.
QualityInspection, electrical test, labels, traceability and packaging?Creates an objective acceptance standard.

Important: Ratings differ by exact part number, contact layout, cable and assembly condition. Values shown on a family page are selection guidance, not a substitute for the approved product drawing and datasheet.

Typical applications and design priorities

Sensors

For sensors, engineers normally prioritize connection security, routing space and service access. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Actuators

For actuators, engineers normally prioritize signal integrity, environmental protection and repeatable installation. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Distributed I/O

For distributed I/O, engineers normally prioritize connection security, routing space and service access. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Machine controls

For machine controls, engineers normally prioritize signal integrity, environmental protection and repeatable installation. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

Instrumentation

For instrumentation, engineers normally prioritize connection security, routing space and service access. Document the mating part and operating conditions so the connector, cable and termination can be evaluated as one system.

How to compare candidate products

Begin with non-negotiable interface requirements, then compare environmental and assembly details. Do not use a single headline rating as the sole decision. A suitable candidate should match the mating geometry, contact map, electrical load, cable construction, mounting envelope and maintenance method.

For replacement projects, send photographs only as supporting information. Measurements, existing part numbers, panel cutouts and pin assignments are needed because many circular connectors have similar external shapes. For new designs, reserve space for the connector body, coupling action, minimum cable bend radius and an operator’s hand or assembly tool.

RFQ checklist

  • Target quantity, prototype quantity and annual demand.
  • Connector family, mating component or interface drawing.
  • Contact count, gender, coding, keying and pin assignment.
  • Voltage, current, signal type, network protocol and shield strategy.
  • Mounting method, panel thickness and available installation space.
  • Cable type, length, conductor size, flex requirements and jacket material.
  • Ingress protection, temperature, vibration and chemical exposure.
  • Required tests, labeling, documentation and packaging.

Frequently asked questions

What is M12 A-Coded used for?

A coding covers the broadest contact-count range in the supplied M12 catalog and is the primary search path for sensor and general signal connections. Common uses include sensors, actuators, distributed I/O. Final suitability depends on the selected part number and operating conditions.

How do I select the correct M12 A coded connector?

Start with the mating interface, electrical function and environment. Then confirm mounting, contact layout, termination, cable diameter and keying. The selection checklist on this page captures the minimum information needed for an engineering review.

Are all M12 A coded connector products interchangeable?

No. Products that look similar may differ in thread, shell size, keying, contact layout, insert orientation, sealing and dimensions. Always compare the complete dimensional drawing and mating-part definition.

Which specifications should I send for a quotation?

Send quantity, drawings or mating part, contact count, pinout, voltage and current, signal or protocol, cable type and length, environmental rating, mounting style and any testing or labeling requirements.

Can LMConn configure a custom version?

Configuration can cover contact layout, cable length, connector orientation, pin mapping, shielding, overmolding, labels and packaging where technically feasible. A drawing review is required before production.

How is the final part verified?

Verification should be defined by the project and may include dimensional inspection, continuity, insulation resistance, contact resistance, high-potential testing, shield continuity and visual checks. Required tests must be agreed in the specification.

Need a connector selected or a cable built around your equipment?

Discuss your project